Semi Interface Magazine

The leading publication at the forefront of semiconductor innovation

Semi Interface Magazine is Oxford Instruments Plasma Technology’s dedicated publication focusing on the dynamic world of compound semiconductors. Launched to share insight, expertise, and thought leadership, the magazine features contributions from industry professionals, researchers, and our own specialists. Each edition explores insights, trends, innovations, and challenges shaping the sector—spanning topics at the forefront of semiconductor technologies. With a mission to inform and inspire, Semi Interface Magazine is a valuable resource for engineers, scientists, and decision-makers driving the future of the semiconductor industry.

Talk to our Expert

Highlights


XXX

We’re excited to bring you Semi Interface Issue #5: Opto datacom Edition, where we explore the innovations and collaborations shaping the future of technology. In this edition, we highlight the exciting breakthroughs that are advancing AI, AR wearables, silicon photonics, and more—pushing the boundaries of connectivity, datacentres, and intelligent machines.

At Oxford Instruments, we are privileged to work alongside industry leaders and researchers to tackle some of the most complex challenges in semiconductor manufacturing. Working with Coherent and AOI, we are at the leading-edge of indium phosphide (InP) technology, including 6-inch wafer processing. Our collaboration with Quantemol on tailored waveform biasing (TWB) could enable next-generation fabrication capability, which is an exciting development in plasma innovation.

We also shine a spotlight on our new state-of-the-art technical training suite in Bristol, UK, designed to empower our customers with the skills and knowledge to optimise system performance and operational efficiency. Join us as we share these stories and more, highlighting our service strategy, people, technologies, and partnerships driving industry transformation.

AAA

AAA1

AAA1

BBB

BBB1

BBB22

Fabrication

Nanoscale electrical characterization is key to understand the performance of semiconductor devices as well as potential failure modes. One widely used technique for this is Atomic Force Microscopy (AFM). 

Using a large number of complementary AFM techniques such as scanning microwave impedance microscopy (sMIM) Kelvin probe force microscopy (KPFM) and conductive AFM it is possible to characterize the majority of material properties in your semiconductor device system, from simple I-V curves to dopant concentrations maps (down to 1014 atoms/cm3). 

The ability of our Cypher and MFP-3D AFMs to combine a number of these techniques allows you to fully understand and optimise your device performance.

Once a failure is identified and located in a device it is usually necessary to remove that structure for further analysis either in a different instrument (e.g. transmission electron microscope) or to achieve a more favourable set of conditions in the same instrument (e.g. Focused ion beam). 

The demands of the semiconductor industry require a repeatable process with a typical time of less than 30 minutes per sample. The difficulty of this task is further increased as devices head towards the 3 or 5 nm node as this requires specimen thicknesses to be less than 20 nm. 

OmniProbe 400 is the perfect tool to achieve all of this the piezo-driven motion allows repeatable positioning at the 10nm scale whilst the concentric rotation allows advanced preparation geometries to be achieved with ease, this leads to the highest possible quality specimens.

For failure analysis in semiconductor devices metallised layers must be exposed. This becomes ever more challenging as node sizes in devices become smaller and architectures become ever more 3 dimensional. 

Our Plasma assisted etch tools ensure that multiple semiconductor compounds whether it be oxides, nitrides or polymides are removed accurately without lifting or damaging the metallisation. 

Our flexible FA tool allows die deprocessing up to 10x faster than the previous process to ensure maximum throughput and productivity.

Once a failed device has been found and isolated from the rest of the die, the true detective work begins to identify the root cause of that failure. The cause of that failure could be due to inconsistency in the chemistry of the process, foreign contaminant particles or variation in crystalline structure of deposited material amongst many other possibilities. 

Many of these potential fault causes are extremely small, typically on the order of a few nanometres. Our latest generation Ultim Extreme energy dispersive x-ray spectrometer (EDS) allows you to work at the same conditions that you would image in the SEM to get elemental information at 10 nm resolution on bulk devices.

In the TEM our Ultim Max TEM detectors are powered by AZtecTEM to ensure the higher possible accuracy quantitative analysis at the highest possible resolution.

For the data storage industry, understanding the nanometre scale magnetic behaviour of magnetic disk media is crucial to understanding its performance in the final device. Magnetic force microscopy (MFM) allows the direct imaging of magnetic domain structure of disk media and other magnetic devices. 

Whether in the analysis of magnetically recorded bits or in the performance of transducers that read/write them, our MFP-3D Infinity AFM with variable field module (VFM) allows accurate analysis of the most challenging specimens.


Facing challenges in your field of work?

Our application experts can help! Submit your queries, and let our experts help resolve your challenges, enabling you to achieve groundbreaking results in your field of work. 

We're committed to supporting your research and advancing scientific discovery.


Get in touch with our Application Experts